When commercial roofing integrity is the priority, the Ace #15 FATnSTRONG™ series, distributed by A1A Wholesale Supply, delivers industry-leading pull-out resistance and durability. These fasteners are designed to work seamlessly with Ace Insulation and Membrane Plates, providing a complete attachment solution for base sheets and modern synthetic membranes.
Each fastener features a high-performance drill point and a #3 Phillips drive head, allowing for rapid penetration into 18 to 22-gauge steel and various wood structural decks. The Black e-coat finish is rigorously tested (exceeding 15 cycles of Kesternich DIN 50018), ensuring that the fastener maintains its structural strength even in corrosive environments. With a specialized 13-thread-per-inch design, FATnSTRONG™ screws offer exceptional stability and torque performance, minimizing the risk of fastener back-out.
Product Details
Manufacturer: Ace Screws.
Material: Heat-treated SAE 1022 Steel.
Coating: Black e-coat (Exceeds FM 4470 Requirements).
Head Style: #3 Phillips Drive.
Thread Count: 13 Threads per Inch.
Compliance: ASTM F6096/F606M-2019; DIN 50018 (Kesternich).
Length Range: 1-1/4” to 24”.
Features & Benefits
Extreme Pull-Out Strength: Tested at over 699 lbs in 22 Ga steel and 685 lbs in 19/32″ plywood for maximum uplift protection.
Advanced Corrosion Resistance: Tested to <15% red rust after 15 Kesternich cycles, ensuring long-term performance under roofing membranes.
High Performance Drill Point: Engineered for fast engagement and reduced installer fatigue, even in heavy-gauge steel decks.
Versatile Sizing: One of the widest length ranges in the industry, capable of securing ultra-thick insulation boards up to 24 inches.
Precision Driving: Used with a #3 Phillips tip to prevent cam-out and ensure consistent seating of the fastener and plate.
Installation Guidelines
Drive Speed: Use a variable-speed screw gun (0-2500 RPM) for optimal results.
Steel Decks: Fastener must penetrate through the deck by a minimum of 3/4″.
Wood Decks: Fastener must penetrate into or through the deck by a minimum of 1″.
Caution: Avoid over-driving or under-driving; ensure threads are fully engaged according to technical specifications.
Technical Specifications & Performance
| Property | Average Performance |
| Tensile Strength | 4,467 lbf |
| Shear Test | 2,124 lbf (22 Ga, 80 Grade) |
| Torque Test | 137 lbf-in |
| Kesternich Test | <15% red rust (Exceeds FM 4470) |
Packaging & Part Numbers (Selection)
| Length | Part # | Pieces/Pail | Weight/Pkg |
| 1-1/4” | ACE-FS15-114INB | 1,000 | 14 lbs |
| 3” | ACE-FS15-3INB | 1,000 | 33 lbs |
| 6” | ACE-FS15-6INB | 500 | 32 lbs |
| 12” | ACE-FS15-12INB | 500 | 61 lbs |
| 24” | ACE-FS15-24INB | 125 | 32 lbs |